Case Setup

Enhancement

Probe Outputs
Multiple enhancements have been made to the surface and volume probe contexts:
  • Import probe .csv files directly in the guide bar to create probe instances.
  • Output variables are accessible from the micro dialog advanced menu selection.
  • Surface probes support a radius parameter.
Outputs
  • New option to delete original dataset after merging for relevant output instances.
  • New set of options to coarsen volume output, both global and per instance settings.
  • New variables, velocity magnitude, std. deviation and variance of pressure, for relevant output instances.
  • Section cuts support parameter for triangulation.
  • Monitoring surfaces have a default color and transparency to differentiate from regular surfaces.
Miscellaneous
  • XML output is less verbose, specifically default walls are skipped from the file.
  • Ground patch has adjustable length and width controls as a fraction of the vehicle’s dimensions.
  • Default names for offset and volume refinement zones have underscores instead of spaces.
  • Systems and Move tool contexts have been redesigned and enhanced.
  • Performance increases when interacting with models with large number of parts.
Python API
  • Create ground patch.
  • Multiple variables are now editable, such as: numTimeSteps, machFactor, volumeOutput.xmin, and offsetRefinementZone.name.

Resolved Issues

  • Polynurbs toolset have been enhanced and works without issues.
  • Axis and Center specified in the xml file are not overridden automatically on import.
  • Display/UI sync issues where number typed is not displayed correctly has been fixed.
  • Segmentation error on creating overset fan is fixed.
  • Repeated fan parts are captured and duplicate entries prevented.
  • Special characters like <> in part names are captured and converted to underscores consistently.
  • Push/pull tools on box faces work as expected for the turbulence, mesh refinement and volume output contexts.
  • Installation issues with the Assets folder have been addressed. Client will now gracefully bypass errors due to missing files.
  • Names of surface outputs and probe outputs are now imported from the xml file.
  • Section cuts and probe outputs accept display color adjustments.
  • Defaults button for advanced mesh control dialog has been fixed.
  • Probes micro dialog correctly resets on creating another probe and all options are available.
  • Probe locations are updated live in graphics when the table is updated.
  • Offset layers and distance fields are in sync when one of them is updated.
  • Turbulence source height is prevented from being set to 0.
  • Negative coefficients are supported for a virtual fan model.
  • Wind tunnel velocity is not reset while selecting the arrow.
  • Probe files are imported without errors if the last line does not contain a line feed.
  • Files in the exported folder are not automatically deleted when a new simulation is exported.
  • Turbulence zone extents change correctly when edited from property editor.
  • Frontal area in the controls panel has the correct units.
  • MRF volumes have a separate category in the part browser.