<output>

The <output> category specifies the main parameters for various types of simulation output.

<output> - <general>

Thermal simulation inherits from all parameters in the output section of the non-thermal simulation. There are additional parameters for thermal:
<avg_start_coarsest_iteration_thermal>
Specifies after which coarsest iteration the continuous averaging of thermal variables. If not specified, the information from <avg_start_coarsest_iteration> will be used.
<avg_window_size_thermal>
Specifies the number of consecutive coarsest iterations that will be used for window averaging of thermal variables. This value should be a factor of <output_frequency>. If not specified, the information from <avg_window_size> will be used.
Output variables can include the variables listed in the table.
Note: If <thermal_method> is set to off then thermal outputs will be set to false as no data is available. Default thermal variables unless you enter a different value in xml.
Table 1. Overview of Available Thermal Output Options for Section Cut, Volume Data, and Surface Data
Full Data Surface Section Cut Partial Surface Partial Volume
temperature Default Default Default Default Default
time_avg_temperature Default Default Default Default Default
window_avg_temperature Default Default Default Default Default
wall_heat_flux Optional Optional Optional Optional Optional
time_avg_wall_heat_flux Optional Optional Optional Optional Optional
window_avg_wall_heat_flux Optional Optional Optional Optional Optional